Case study · Sonoma County, California

Fountaingrove: rebuilding where the Tubbs Fire burned

The 2017 Tubbs Fire burned across this part of Fountaingrove, and it is still rebuilding. We built a digital twin of about 45 hectares of it, down to every building and tree, solved the wind field with CFD, and ran 640 fire simulations to map the risk to each building.

Buildings modeled
81
Measured heights from lidar
Trees resolved
1,457
Height and crown from lidar
CFD mesh cells
405k
Refined around buildings and canopy
Mean local wind
7.1 m/s
Peak 16.7 m/s, from N
Risk map of Fountaingrove, Santa Rosa. Burn probability is highest in the open grassland and scattered trees to the north-east and south and on the wooded slope to the west. The large buildings along that western slope are mostly severe, while the rebuilt cul-de-sac in the center is mostly lower risk. Of 81 buildings, 23 are severe, 7 elevated, 12 moderate and 39 lower risk.
The risk map

How often fire reached each home

One fire run shows one possible outcome, so we ran 640. They cover every dry, windy day in five years of local weather, with fire arriving from each of eight directions. Shading shows how often the fire reached each spot. Each building is colored by how often it ignited.

0.2–55%
range of ignition frequency across 81 buildings in one neighborhood
23 of 81
buildings ignite in 30% or more of fires, and 39 in under 10% of them
640
fire simulations: 40 fire-weather days × 8 directions × 2 random seeds

Burn probability

Share of simulated fires that reach each 4 m cell

Home risk tier

  • Lower · under 10%
  • Moderate · 10–20%
  • Elevated · 20–30%
  • Severe · 30% or more

Share of simulated fires in which the home ignites

Assumes a fire reaches the neighborhood under local fire weather, with every direction and weather day weighted equally. The results are uncalibrated and rank buildings within this neighborhood only. They are not annual probabilities or prices.

What it shows

What the neighborhood model shows

  1. 01

    Wind is not uniform

    Local wind at 10 m ranges from near calm to almost 17 m/s. About half of the sampled points see less than half the reference speed, sheltered by terrain, buildings and canopy.

  2. 02

    Surroundings set the risk

    Buildings backing onto the wooded western slope ignite in up to 55% of simulated fires. Homes on the rebuilt cul-de-sac, ringed by pavement and irrigated yards, mostly ignite in under 10%.

  3. 03

    Exposure follows the flow

    In the scenario, 38 of 81 buildings ignite within 30 minutes, half in the first 15. Fire enters from the wildland edge and runs downwind, and neighbors end up with different outcomes.

What we ran

  1. 01

    Property and terrain data

    Building footprints, 7.9 million aerial lidar points, high-resolution imagery and fuel and vegetation layers, fused into one model of a 0.66 × 0.68 km area.

  2. 02

    3D geometry

    Lidar gives each building its measured height and each tree its height and crown. Terrain comes from the same survey.

  3. 03

    Weather scenario

    From five years of local hourly weather we chose the windiest dry, warm hour: 8.3 m/s from the north, gusting to 18.6 m/s, at 13% relative humidity.

  4. 04

    CFD wind field

    Our CFD engine resolves the flow over the terrain, around 79 buildings, and through tree crowns modeled as porous zones.

  5. 05

    Illustrative fire scenario

    A separate surface-fire model ignites at the northern edge under the same weather and runs for 30 minutes. It shows one way a fire can spread through the neighborhood.

  6. 06

    Risk ensemble

    The same fire model, run 640 times for one simulated hour each across local fire weather and ignition directions, gives every cell a burn probability and every building an ignition frequency.

What it does not show

  • The CFD solve ran 1,000 iterations but did not meet its convergence thresholds. Treat the wind field as preliminary.
  • The fire runs, including the risk ensemble, use a separate surface-fire model with uniform hourly wind. They are not driven by the CFD wind field.
  • The risk map weights every ignition direction and fire-weather day equally and leaves out how likely ignition is and any firefighting response. It ranks buildings against each other; it is not calibrated against observed losses.
  • Some homes rebuilt since the Tubbs Fire are not yet in the building inventory, so the newest lots are under-counted. The source data were captured in different years, so the model is not a survey of current conditions.
  • Building materials and vulnerability use default assumptions because no inspection records exist for this area. A building that rarely ignites in the simulations is not safe.

Where this goes next

Toward a fast model for every property

Converged, validated CFD fields coupled to ember and fire physics, run across many weather scenarios per home. That is the training data behind Sage’s fast property risk model.

Know your property before disaster does

See how storm, flood, wildfire and earthquake reach its roof, its floor and its lot.